Fendt 300 Vario COM III — Vario Tractors - Fault Codes

Faults wrong 08.1.A0 A024 ECU, EPC B 08.1.A1 A024 ECU, EPC B Fault code Id code Brief description Description 1E.1.00 A051 EDC engine control unit Undefined error 08.1.51 B032 Left draft sensing pin, rear power lift overload 08.1.B0 B030 Position sensor, rear power lift Position sensor not calibrated 08.1.B2 A035 Rotary switch, setpoint setting not calibrated 1E.1.02 B092 Boost pressure sensor 1E.1.03 B092 Boost pressure sensor range 1E.1.04 B089 Coolant - temperature sensor target range 1E.1.01 G001 Battery range. 01.1.E0 A002, B035 A002 - ECU (enhanced control) ; EDC / EMR hand throttle sensor Capitel Docu-No.

Index Date Version Page Vario Tractors - Fault Codes 12.06.2006 0000 000022 B b 15/21 12.06.2006 Date b Version 15/21 Page Vario Tractors - Fault Codes 0000 Capitel B Index 000022 Docu-No.

Fault code Id code Brief description Description Consequences Link FENDIAS / Note 08.1.51 B032 Left draft sensing pin, rear power lift Draft sensing pin left overload Reduce load on draft sensing pin Circuit diagram 'Electrohydraulic lifting gear control' Rear EPC 08.1.A0 A024 ECU, EPC B Checksum incorrect EOL programming 08.1.A1 A024 ECU, EPC B Checksum incorrect EOL programming 08.1.B0 B030 Position sensor, rear power lift Position sensor not calibrated Position setting no longer possible Circuit diagram 'Electrohydraulic lifting gear control' Rear EPC calibration code " 8002" 08.1.B2 A035 Rotary switch, setpoint setting Setpoint potentiometer not calibrated Setpoint can no longer be set Circuit diagram 'Electrohydraulic lifting gear control' Rear EPC calibration code ' 8001' 01.1.E0 A002, B035 A002 - ECU (enhanced control) ; EDC / EMR hand throttle sensor EEPROM checksum is wrong limited driving operation, Chapter 2000 Reg.B 'EDC control' circuit diagram End-of-line programming required or load new data record 1E.1.00 A051 EDC engine control unit Undefined error Read error out with SERDIA SERDIA 1E.1.01 G001 Battery Battery input, battery voltage outside target range.

Starting not possible SERDIA (clear fault) 1E.1.02 B092 Boost pressure sensor Boost pressure sensor, cable break or short circuit. Boost pressure outside target range Reduced performance Circuit diagram 'Deutz engine control' SERDIA (clear fault) FC:0020, 0021 1E.1.03 B092 Boost pressure sensor Charge air temperature sensor, cable break or short circuit. Charge air temperature above target range Reduced performance Circuit diagram 'Deutz engine control' SERDIA (clear fault) FC:0095, 0096 1E.1.04 B089 Coolant - temperature sensor Coolant temperature sensor, cable break or short circuit.

Coolant temperature outside target range Circuit diagram 'Deutz engine control' SERDIA (clear fault) FC:0037, 0038 Faults