Komatsu — CHECK AND MAINTENANCE AIR CONDITIONER

. MAINTENANCE MAINTENANCE PROCEDURE CHECK AND MAINTENANCE AIR CONDITIONER Check Level of Refrigerant (gas) WARNING REMARK Inspection and Maintenance Items 4 - 36 If the refriger ant used in the air c onditioner ge ts into your eyes o r on your hands, i t may cause loss of sight or frostbite. Do not touch the ref rigerant. Never loo sen any part o f the refrigerant ci rcuit. as is leaking. Do not bring any flame close to any point whe re the refrigerant g as is leaking. If the level of the refrigerant (gas) is low, the cooling effec t will be reduced.

R un the engine at high idle, a nd check the flo w of the refrigerant gas (R134a) in th e refrigerant circuit through t he sight glass (2) (in running at h spection window) of the receiver (1) when the cooler is igh speed. (A) No bub (B) Some b bles in refrigerant ubbles in flow (bu flow: Suitab bbles pass Lack of refr (C) Colorles When there are bubbles, the refrigerant g as level is low, so contact your Koma tsu distributors t o have refri gerant added. If the air conditioner is run with the r damage to Inspection During Off Season Even during the off-season, operate the a ir conditioner for 3 to 5 minutes o nce a month to m aintain the oil film at al parts of the compressor.

Check, maintenance items Guideli Content of check, maintenance ne for maintenance interval Refrigerant (gas) Charge amount Twice a y ear (spring, autumn) Air conditioner condenser Clogged fins Every 500 hours Compressor Operating condition Every 400 0 hours V-belt Damage, tension Every 250 hours Blower motor, fan Operating condition When req (does it make abnormal noise?) uired Control mechanism Operating condition (does it function normally?) When req uired Piping mounts Mounting condition, looseness at tightening or When req connecting portions, leakage of gas, damage uired