Komatsu — STARTING ENGINE

. MULTI-MONITOR SPECIFICATION MACHINE OPERATIONS AND CONTROLS Starting Engine in Cold Weather WARNING 7 - 35 Start t he engine only after si tting down in the operator' Do no t attempt to start the e ngine by short-circuiting the engine starting circuit. Such an act may cause a serious bodily i njury or fire Check that there are no pers ons or obstacles in the sur rounding a rea, t hen sound the horn and Never use starting aid fluids as they may cause explosi Exhau st gas is toxic. When starting the engine in confin ed spaces , be particularly careful to ens NOTICE Before starting the engine, c heck that fuel control dial (2) is at the low idle (M If the f sudde IN) position.

uel control dial is at th nly and cause dam e FULL position, the engine will accelerate age to the engine parts, set it to an intermediate or low speed position. Do not keep the strating motor rotating continuously for more than 20 seconds. If the e 2. ngine fails to start, wait for about 2 minutes and repeat from Step When st arting in low tempe 1. Che ck the lock lever (1) is at the LOCK position (L). If the l ock r is in the FREE po sition (F), the engine doe s not star 2. Set fuel control dial (2) at a low idle (MIN) positi on. Do n ot set fuel control d ial (2) at the high idle (M AX) position.