5. Failure Diagnosis P0103 MAF sensor electrical high fault 1. Overview 2. Condition for Running Diagnostic Key on or engine run 3. Condition for Setting the Fault Code Air mass flow value is more than maximum operation frequency 4. Condition for Clearing the Fault Code Air mass flow value is in operation range 5. Inspection Items 5 - 43 Code Causes Impact P0103 Electrical problem Connection problem Sensor problem CE lamp ON Torque Reduction Lv0 NO ECU Pin Description 1 235 Air Inlet Temperature, analogue signal 2 137 Supply Voltage (5V) 3 120 TMAF Sensor Return 4 228 Air Mass Flow Sensor, frequency signal Step Inspection Standard Value YES NO 1 P0103 is occurred on diagnostic tool?
Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 VEXT fault present? Step 4 Step 5 4 Problem with one of these sensors causing loss of Vext: Disconnect sensors one by one checking if fault disappear to find which one is faulty. If None is found faulty, check short circuit and isolation of Vext lines on the harness Step 5 5 Check sensor connection Connection problem? Do necessary repair Step 6 6 Check sensor resistance (checking it is coherent with vehicle conditions) if applicable. Resistance problem? Change sensor Step 7 7 Check ECU connection Connection problem? Do necessary repair Step 8 8 Check continuity and electrical insulation Electrical problem?
Fix harness Call Hot-line