5. Failure Diagnosis 2) B 5 - 54 Step Inspection Standard Value YES NO 6 Please fix the faulty wire or clean the water. After fix the problem, start the engine and change the RPM from low idle to high idle. Please keep the RPM as a high idle at least 10 minutes. Fault code is cleared? O.K Step 7 7 Please do the Shut off test & Run up test for detecting which injector has fault or not. Do you find faulty injector? Step 7 Step 8 8 Change the injector which has a fault as a normal one. Start the engine and set the RPM in high idle at least 10 minutes. Fault code is cleared? O.K Step 9 9 Change the ECU as a new one. Start the engine and set the RPM in high idle at least 10 minutes.
Fault code is cleared? O.K Step 10 10 Change the high pressure pump with DOOSAN A.S support. Fault code is cleared? O.K Call DOOSAN Hot line Step Inspection Standard Value YES NO 1 P0089 is occurred on diagnostic tool? Step 2 2 Fault of type IMV or rail pressure sensor? First, fix the corresponding fault Step 3 3 DTC link to High Pressure control? Step 4 No problem 4 Check that: * fuel feed circuit is in good condition * there is diesel fuel present in the system * there is no air (no bubbles or emulsion in the pipes) * there is enough fuel pressure in inlet pump * there are no high pressure circuit leaks * there is diesel fuel of the correct quality and type Low pressure circuit faulty?
Repair the low pressure circuit Step 5 5 According to engine start or not, different tests are to be done. Does engine start? Step 6 Step 7 6 Perform "DYNAMIC IMV TEST" Faulty IMV? Replace IMV Step 8 7 Perform "STATIC INJECTOR BACKLEAK TEST" Carry out the "tube test: Result? Replace corresponding injector(s) Replace HP pump 8 Perform "DYNAMIC INJECTOR BACKLEAK TEST" Backleak above limit? Replace corresponding injector(s) Step 9 9 Perform "PUMP PRESSURE BUILD CAPACITY" This test need specific equipment "hydraulic-T" Result? End Replace HP pump