Doosan Infracore D18NAP — P2428 Exhaust over temperature fault

5. Failure Diagnosis P2428 Exhaust over temperature fault 1. Overview 2. Condition for Running Diagnostic During engine running & DPF regeneration is activated 3. Condition for Setting the Fault Code If the turbine in temperature is out of the threshold (over mechanical limit), fault code is raised. 4. Condition for Clearing the Fault Code If the turbine in temperature is within the threshold (within mechanical limit), fault code is cleared. 5.

Inspection Items 5 - 60 Code Causes Impact P2428 Leakage Sensor problem CE lamp ON Torque Reduction Lv0 NO ECU Pin Description 1 123 Exhaust gas temp 2 (Pre-Turbo), Return 2 106 Exhaust gas temp 2 (Pre-Turbo), Signal Step Inspection Standard Value YES NO 1 P2428 is raised on diagnostic tool? Step 2 O.K 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Please do visual inspections between air-filter and exhaust manifold (throughout all air path). Is there any leakage? If you cannot find with your eyes, You can check leakage during engine running with high idle in machine stationary condition. You have to record IN Turbine in temp with high idle condition.

_ _ _ Step 4 Step 6 4 Please fix the leakage. After fix the problem, start the engine and change the RPM from low idle to high idle. Please keep the RPM as a high idle at least 3 minutes. Please record IN Turbine in temp with high idle condition. _ _ _ IN Turbine in temp gets lower after fixing the leakage? _ _ _ Fault code is cleared? Step 5 Step 6 5 Operate the machine what you want to do and please check IN Turbine in temp. _ _ _ Fault code is not occurred again? O.K Step 6 6 Please check the pressure drop after air filter. Is there any clogging or blocking air filter with dust? If pressure drop is out of spec [-5kPa] with rated power, please change the air filter cartridge.

After change the air filter cartridge, start the engine and change the RPM from low idle to high idle. Please keep the RPM as a high idle at least 3 minutes. Please record IN Turbine in temp with high idle condition. _ _ _ IN Turbine in temp gets lower after changing the cartridge? _ _ _ Fault code is cleared? Step 5 Call DOOSAN Hot line