Doosan Infracore D18NAP — P0602 C2I data not programmed

5. Failure Diagnosis P0602 C2I data not programmed 1. Overview 2. Condition for Running Diagnostic Key on 3. Condition for Setting the Fault Code If the C2I data of ECU is not matched with each injector 4. Condition for Clearing the Fault Code If the C2I data of ECU is matched with each injector 5. Inspection Items 5 - 67 Code Causes Impact P0602 Injector C2I data is not matched or corrupted CE lamp ON Torque Reduction Lv1 Limp-home mode Step Inspection Standard Value YES NO 1 P0602 is occurred on diagnostic tool? Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Re-Write (CxI), respecting power down and up delay and taking care of injector position.

Then erase faults Fault disappeared? Problem solved Step 4 4 Check power relay operation. Relay not operation? Fix relay or wiring Step 5 5 Check ECU connection. Connection problem? Do necessary repair Step 6 6 Check continuity and electrical insulation Electrical problem? Fix Harness Call Hot-line