Doosan Infracore D18NAP — P0265 Wiring harness resistance high fault (Cylinder #2)

5. Failure Diagnosis P0265 Wiring harness resistance high fault (Cylinder #2) 1. Overview 2. Condition for Running Diagnostic During engine running 3. Condition for Setting the Fault Code The injector of cylinder #2 wiring resistance is above the range. 4. Condition for Clearing the Fault Code The injector of cylinder #2 wiring resistance it in a range 5. Inspection Items 5 - 93 Code Causes Impact P0265 Electrical problem Connection problem Wiring fault No NO ECU Pin Description 1 175 Fuel Injector LSD1B 2 151 Fuel Injector HSD1B Step Inspection Standard Value YES NO 1 P0265 is occurred on diagnostic tool?

Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Perform injector buzzing test Test addible? Call Hot-line Step 4 4 Key off and check injector connection Connection problem? Do necessary repair Step 5 5 Check resistance of injector. For solenoid, it should be less than 1 For Piezzo, it should be around 1M and should settle within some 10s. Resistance incorrect? Step 11 Step 6 6 Swap connection between 2 injectors if harness enable it Same problem still present? Step 11 Step 7 7 Check continuity and electrical insulation Electrical problem? Do necessary repair Step 8 8 If intermediate engine connector is present, check it electrically Electrical problem?

Do necessary repair Step 9 9 Check ECU connection Connection problem? Fix harness Step 10 10 Check continuity and electrical insulation Electrical problem? Call Hot-line 11 Change injector. Mandatory: update Individual Corrections (taking care of its position)