Doosan Infracore D18NAP — P02A3 Injector Minimum drive pulse drift (Cylinder #3)

5. Failure Diagnosis P02A3 Injector Minimum drive pulse drift (Cylinder #3) 1. Overview 2. Condition for Running Diagnostic During engine running 3. Condition for Setting the Fault Code If the MDP (Minimum Driving Pulse) of cylinder #3 injector is out of the threshold during restricted condition, fault code is raised. 4. Condition for Clearing the Fault Code If the MDP (Minimum Driving Pulse) of cylinder #3 injector is within the threshold during restricted condition, fault code is cleared 5.

Inspection Items 5 - 102 Code Causes Impact P02A3 Injector of cylinder #3 MDP absolute below the minimum limit CE lamp ON Low idle RPM increase NO ECU Pin Description 1 125 Fuel Injector LSD2A 2 103 Fuel Injector HSD2A Step Inspection Standard Value YES NO 1 P02A3 is occurred on diagnostic tool? Step 2 2 After let the machine is in safety area and turn-off the key switch. Step 3 3 Check if new software that solves this problem is available or if SW is up to date. Upgrade possible? Re flash SW Re Write I2C Step 4 4 Check that individual injector corrections (I2C) are correctly entered in ECU. Check particularly position and value Problem of IC?

Re Write I2C Step 5 5 Check accelerometer connection and screwing torque. Mandatory: Check particularly ground shield connection of accelerometer Connection problem? Do necessary Call Hot line