Doosan Infracore D18NAP — P0007 Rail pressure control error (IMV resistance trim value is too high)

5. Failure Diagnosis P0007 Rail pressure control error (IMV resistance trim value is too high) 1. Overview 2. Condition for Running Diagnostic During engine running 3. Condition for Setting the Fault Code If the resistance of IMV trim value is higher than threshold, fault code is raised. 4. Condition for Clearing the Fault Code If the resistance of IMV trim value is within the threshold, fault code is cleared. 5.

Inspection Items 5 - 107 Code Causes Impact P0007 Electrical problem Connection problem Resistance problem CE lamp Flashing Torque Reduction Lv1 Delay engine stop NO ECU Pin Description 1 177 Inlet Metering Valve PWM 2 - Pbatt Step Inspection Standard Value YES NO 1 P0007 is occurred on diagnostic tool? Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Check the IMV connection Connection problem? (pin to pin) Do necessary repair Step 4 4 Check the ECU Connection. Connection problem? Do necessary repair Step 5 5 Check continuity and electrical insulation. Electrical problem? Fix wire harness Step 6 6 Measure IMV electrical resistance?

(around 5.3 at 20°C) Resistance problem? Change IMV Step 7 7 Perform IMV buzzing test? (Test not applicable) IMV is buzzing? Call Hot-Line Change IMV