5. Failure Diagnosis P2081 Turbo in temperature sensor noisy fault 1. Overview 2. Condition for Running Diagnostic During engine running 3. Condition for Setting the Fault Code There is not turbine in temp sensor fault and there is a noise spike on the sensor signal. (Noise detect: If the absolute difference, comparing the raw actual temp to low pass filtered temp value, exceeds calibration value). 4. Condition for Clearing the Fault Code The noise spike is restored. 5.
Inspection Items 5 - 125 Code Causes Impact P2081 Electrical problem Connection problem Sensor problem Noise CE lamp ON Torque Reduction Lv0 NO ECU Pin Description 1 123 Exhaust gas temp 2 (Pre-Turbo), return 2 106 Exhaust gas temp 2 (Pre-Turbo), signal Step Inspection Standard Value YES NO 1 P2081 is occurred on diagnostic tool? Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 VEXT fault present? Step 4 Step 5 4 Problem with one of these sensors causing loss of Vext: Disconnect sensors one by one checking if fault disappear to find which one is faulty.
If None is found faulty, check short circuit and isolation of Vext lines on the harness Step 5 5 Check sensor connection Connection problem? Do necessary repair Step 6 6 Check sensor resistance (checking it is coherent with vehicle conditions) if applicable. Resistance problem? Change sensor Step 7 7 Check ECU connection Connection problem? Do necessary repair Step 8 8 Check continuity and electrical insulation Electrical problem? Fix harness Call Hot-line