Doosan Infracore D18NAP — P062E Injector Bank 2 electric or SPI fault

5. Failure Diagnosis P062E Injector Bank 2 electric or SPI fault 1. Overview 2. Condition for Running Diagnostic During engine running 3. Condition for Setting the Fault Code The injector bank 1 high side driver feedback voltage is constantly monitored. If the voltage is lower/higher than the calibrated threshold, then the fault is set. or SPI (Serial Peripheral Interface) has a problem 4. Condition for Clearing the Fault Code The injector bank 1 high side driver feedback voltage is constantly monitored. If the voltage is inside the calibrated threshold range, then the fault is cleared. 5.

Inspection Items 5 - 130 Code Causes Impact P062E Injector bank #2 has shorted to ground or battery or SPI (Serial Peripheral Interface) fault CE lamp Flashing Low idle RPM increase (SPI fault - CE lamp ON Torque Reduction Lv0) NO ECU Pin Description 1 175 Fuel Injector LSD1B 2 151 Fuel Injector HSD1B Step Inspection Standard Value YES NO 1 P062E is occurred on diagnostic tool? Step 2 2 After let the machine is in safety area and turn-off the key switch. Step 3 3 Check injector connections corresponding to fault bank Connection problem? Do necessary repair Step 4 4 Disconnect injectors and key on Problem still present? Step 7 5 Check ECU Connection Connection problem?

Do necessary repair Step 6 6 Clear fault then key off then reconnect ONE injector then key on Problem back? Step 7 Step 8 7 Change corresponding injector Do not forget to write new Individual Injector Correction to ECU Step 8 8 Iterate previous step on all injectors Try another injector (STEP 5) Problem back? Step 7 Step 8 9 Check continuity and electrical insulation Electrical problem? Fix harness Call Hot-line