Doosan Infracore D18NAP — P2144 EGR H-Bridge driver short circuit to ground

5. Failure Diagnosis P2144 EGR H-Bridge driver short circuit to ground 1. Overview 2. Condition for Running Diagnostic Key on or engine run 3. Condition for Setting the Fault Code If the pins of EGR H-bridge have been shorted to battery then fault code is arisen. 4. Condition for Clearing the Fault Code The fault status is removed 5. Inspection Items 5 - 132 Code Causes Impact P2144 EGR H-bridge Driver is shorted to ground CE lamp ON Torque Reduction Lv0 NO ECU Pin Description 1 193 EGR (H-Bridge Neg) 2 164 EGR, VREF3 3 - Not used 4 172 EGR Sensor Return GND 5 192 EGR (H-Bridge Pos) 6 116 EGR Position Sensor Signal Step Inspection Standard Value YES NO 1 P2144 is occurred on diagnostic tool?

Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 VEXT fault present? Step 4 Step 5 4 Problem with one of these sensors causing loss of Vext: Disconnect sensors one by one checking if fault disappear to find which one is faulty. If None is found faulty, check short circuit and isolation of Vext lines on the harness 5 Connection conform Problem still present? Do necessary repair Step 6 6 Visually check device Device problem? Change device Step 7 7 Check ECU connection Connection problem? Do necessary repair Step 8 8 Check continuity and electrical insulation Electrical problem? Fix harness Step 9 9 Change device Problem still present?

Call Hot-line Problem solved