Doosan Infracore D18NAP — P0404 EGR position control fault

5. Failure Diagnosis P0404 EGR position control fault 1. Overview 2. Condition for Running Diagnostic Key on or engine run 3. Condition for Setting the Fault Code EGR valve is not operating as normally. 4. Condition for Clearing the Fault Code EGR valve is operating as normally. 5. Inspection Items 5 - 134 Code Causes Impact P0404 EGR valve control fault CE lamp ON Torque Reduction Lv0 NO ECU Pin Description 1 193 EGR (H-Bridge Neg) 2 164 EGR, VREF3 3 - Not used 4 172 EGR Sensor Return GND 5 192 EGR (H-Bridge Pos) 6 116 EGR Position Sensor Signal Step Inspection Standard Value YES NO 1 P0404 is occurred on diagnostic tool?

Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Check air inlet circuit: * Valve state * Depression circuit * Vacuum value pump * Open solenoid valve * Vanne state * Air inlet valve functionality Step 4 4 Check connection of the valve Check that the supply voltage is correct Check that the valve position can reach MIN to MAX position (0% to 100%) If applicable, launch a learning of EGR position Problem of connection / supply / position? Do necessary repair Problem solved