Doosan Infracore D18NAP — P0651 5V Supply #2 fault

5. Failure Diagnosis P0651 5V Supply #2 fault 1. Overview 2. Condition for Running Diagnostic Key on or engine run 3. Condition for Setting the Fault Code If VREF voltage from ECU is not in normal range, then the fault is set 4. Condition for Clearing the Fault Code If VREF voltage from ECU is in normal range, then the fault is cleared. 5. Inspection Items 5 - 136 Code Causes Impact P0651 ECU sensor supply voltage(Vext2) Fault CE lamp Flashing Torque Reduction Lv0 Engine will be stopped NO ECU Pin Description 1 VREF2(Voltage) Step Inspection Standard Value YES NO 1 P0651 is occurred on diagnostic tool? Step 2 2 After let the machine be in safety area and turn-off the key switch.

Step 3 3 DTC of all corresponding sensors connection to this sensor supply voltage (Vext)? Step 4 Step 5 4 Problem with one of these sensors causing loss of Vext: Disconnect sensors one by one checking if fault disappear to find which one is faulty. If None is found faulty, check short circuit and isolation of Vext lines on the harness 5 Connection conform Problem still present? Call Hot-Line Problem solved