5. Failure Diagnosis P025C IMV drive electrical fault (SCGND) 1. Overview 2. Condition for Running Diagnostic Key on or engine run 3. Condition for Setting the Fault Code If the IMV signal is shorted to ground, fault code is raised. 4. Condition for Clearing the Fault Code If the fault condition is restored, fault code is cleared. 5. Inspection Items 5 - 139 Code Causes Impact P025C Electrical problem Connection problem Resistance problem Failure of IMV CE lamp Flashing Torque Reduction Lv1 NO ECU Pin Description 1 177 Inlet Metering Valve PWM 2 - Pbatt Step Inspection Standard Value YES NO 1 P025C is occurred on diagnostic tool?
Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Check the IMV connection Connection problem? (pin to pin) Do necessary repair Step 4 4 Check the ECU Connection. Connection problem? Do necessary repair Step 5 5 Check continuity and electrical insulation. Electrical problem? Fix wire harness Step 6 6 Measure IMV electrical resistance? (around 5.3 at 20 °C) Resistance problem? Change IMV Step 7 7 Perform IMV buzzing test? (Test not applicable) IMV is buzzing? Call Hot-Line Change IMV