Doosan Infracore D18NAP — P0406 EGR actuator position feedback signal high fault

5. Failure Diagnosis P0406 EGR actuator position feedback signal high fault 1. Overview 2. Condition for Running Diagnostic Key on or engine run 3. Condition for Setting the Fault Code EGR Feedback Position value is more than maximum operation range 4. Condition for Clearing the Fault Code EGR Feedback Position value is in operation range 5.

Inspection Items 5 - 14 Code Causes Impact P0406 Electrical problem Connection problem Sensor problem CE lamp ON Torque Reduction Lv0 NO ECU Pin Description 1 193 EGR (H-Bridge Neg) 2 164 EGR, VREF3 3 - Not used 4 172 EGR Sensor Return GND 5 192 EGR (H-Bridge Pos) 6 116 EGR Position Sensor Signal Step Inspection Standard Value YES NO 1 P0406 is occurred on diagnostic tool? Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Check air inlet circuit:

* Valve state * Depression circuit * Vacuum value pump * Open solenoid valve * Vanne state * Air inlet valve functionality Step 4 4 Check connection of the valve Check that the supply voltage is correct Check that the valve position can reach MIN to MAX position (0% to 100%) If applicable, launch a learning of EGR position Problem of connection / supply / position? Do necessary repair Problem solved