Doosan Infracore D18NAP — P0111 Intake Manifold Temperature plausibility fault

5. Failure Diagnosis P0111 Intake Manifold Temperature plausibility fault 1. Overview 2. Condition for Running Diagnostic During engine running 3. Condition for Setting the Fault Code If the T2 temperature is out of the threshold during restricted condition, fault code is raised. 4. Condition for Clearing the Fault Code If the T2 temperature is within the threshold during restricted condition, fault code is cleared. 5.

Inspection Items 5 - 28 Code Causes Impact P0111 Leakage Electrical problem Connection problem Sensor problem No NO ECU Pin Description 1 169 Inlet Boost Temperature, Return 2 194 Inlet Boost Temperature, Signal Step Inspection Standard Value YES NO 1 P0111 is raised on diagnostic tool? Step 2 O.K 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Please do visual inspection between air filter and t2 temperature sensor location. Is there any leakage? If you cannot find with your eyes, You can check leakage during engine running in machine stationary condition. Step 4 Step 5 4 Please fix the leakage.

After fix the problem, start the engine and change the RPM from low idle to high idle. Please keep the RPM as a high idle at least 10 minutes. Fault code is cleared? O.K Step 5 5 Change the T2 temperature sensor as a normal one. Start the engine and set the RPM in high idle at least 10 minutes. Fault code is cleared? O.K Call DOOSAN Hot line