Doosan Infracore D18NAP — P0107 Manifold Pressure sensor electrical low fault

5. Failure Diagnosis P0107 Manifold Pressure sensor electrical low fault 1. Overview 2. Condition for Running Diagnostic Key on or engine run 3. Condition for Setting the Fault Code Manifold pressure sensor value is less than minimum operation pressure 4. Condition for Clearing the Fault Code Manifold pressure sensor value is in operation range. 5. Inspection Items 5 - 33 Code Causes Impact P0107 Electrical problem Connection problem Sensor problem CE lamp ON Torque Reduction Lv0 NO ECU Pin Description 1 161 VREF2, INPRES 2 167 INPRES Return GND 3 112 Intake Manifold Pressure Sensor Step Inspection Standard Value YES NO 1 P0107 is occurred on diagnostic tool?

Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 VEXT fault present? Step 4 Step 5 4 Problem with one of these sensors causing loss of Vext: Disconnect sensors one by one checking if fault disappear to find which one is faulty. If None is found faulty, check short circuit and isolation of Vext lines on the harness Step 5 5 Check sensor connection Connection problem? Do necessary repair Step 6 6 Check sensor resistance (checking it is coherent with vehicle conditions) if applicable. Resistance problem? Change sensor Step 7 7 Check ECU connection Connection problem? Do necessary repair Step 8 8 Check continuity and electrical insulation Electrical problem?

Fix harness Call Hot-line