Doosan Infracore D18NAP — P0116 Coolant temperature plausibility fault

5. Failure Diagnosis P0116 Coolant temperature plausibility fault 1. Overview 2. Condition for Running Diagnostic During engine running 3. Condition for Setting the Fault Code If the coolant temperature is increased more than the threshold during restricted condition, fault code is raised. 4. Condition for Clearing the Fault Code If the coolant temperature is increased higher than the threshold during restricted condition, fault code is cleared. 5.

Check Items 5 - 36 Code Causes Impact P0116 Thermostat problem(broken or normally open), Connection problem Sensor problem No NO ECU Pin Description 1 145 Coolant Temperature Return 2 109 Coolant Temperature Sensor Step Inspection Standard Value YES NO 1 P0116 is occurred on diagnostic tool? Step 2 O.K 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Check the thermostat. Is the thermostat broken? For example thermostat is always wide open. Step 5 Step 4 4 Change the coolant temperature sensor. Start the engine and set the RPM in high idle, 10 minutes. After that set the RPM in low idle, fault code is cleared and torque limit is deactivated?

O.K Call DOOSAN Hot line 5 Change the thermostat as a normal one. Start the engine and set the RPM in high idle, 10 minutes. After that set the RPM in low idle, fault code is cleared and torque limit is deactivated? O.K Call DOOSAN Hot line