MAN — Removing and attaching expansion tank

Removing and attaching expansion tank D Drain coolant, see page 39 Fig. 1 Remove hollow bolt from bleeder line. Remove coolant level sensor. 1 Figs. 2 and 3 Remove the mounting bolts from the brackets of the expansion tank (13 mm and 19 mm). 2 3 Fig. 4 Remove nut (13 mm) from the front side of the ex- pansion tank. Take off the expansion tank. The expansion tank is attached in reverse se- quence. 4 47