MAN — Setting valve clearance

Setting valve clearance Fig. 4 Push feeler gauge between valve stem and rocker arm. Loosen lock nut (17 mm) and turn adjusting screw with screwdriver until feeler gauge can be moved with slight resistance. Tighten lock nut to the specified torque (see “Engineering S Data S Setting values”) using screw- driver to prevent adjusting screw from turning. Check clearance again. Refit cylinder head covers. 4 Fig. 5 If the inspection hole on the flywheel housing is accessible, a device with ratchet (special tool) may be attached there for turning the engine over. 5 87