Komatsu — INSTRUMENTS AND INDICATORS

(10) TURN SIGNAL FUSE HOLDER This is a 15 amp.- dual element, time delay (slow blow) type fuse. Replacement with any other type is not recommended. (11) CIRCUIT BREAKER 5 amp circuit breaker protects the warning cluster and the sound alarm from overloads. If a malfunction occurs, the breaker will open to protect the circuit from overcurrent condition. The circuit breaker can be reset manually by pushing the red reset button. (12) CIRCUIT BREAKER 15 amp circuit breaker protects the steering bleeddown timer from overloads. If a malfunction in the circuitry occurs, the breaker will open the circuit. The circuit breaker can be reset manually by pushing the red reset button.

(13) CIRCUIT BREAKER 30 amp circuit breaker protects the heater blower motor and the air conditioning system from overloads. The circuit breaker can be reset manually by pushing the red reset button. Promptly report to maintenance personnel any burnt out fuses or circuit breakers that need repeated resetting. These may be indications of serious problems that may result in fire or damage to components if neglected. HB5-4 Instruments and Controls HB5014 4/94