Doosan — Doosan D60S-5 and G60S-5 Lift Truck Operation Manual

Maintenance Section Cleaning Primary Filter Elements Water-280 kPa (40 psi) Maximum Pressure Pressure air can cause personal injury. When using pressure air for cleaning, wear a protective face shield, protective clothing and protective shoes. The maximum air pressure must be below 205 kPa (30 psi) for cleaning purposes. NOTICE Direct water on the inside and outside of the element along the length of the pleats. Air dry it thoroughly and then examine it. Do not clean the elements by bumping or tapping them. Detergent Inspect filter elements after cleaning. Do not use a filter with damaged pleats, gaskets or seals. 1. Wash the element in warm water and mild household detergent. 2.

Rinse the element with clean water. See instructions in preceding topic for cleaning with water. 3. Air dry it thoroughly, and then examine it. When cleaning with pressure air, use 205 kPa (30 psi) maximum pressure to prevent filter element damage. When cleaning with pressure water, use 280 kPa (40 psi) maximum pressure to prevent filter element damage. Checking Element Have spare elements on hand to use while cleaning used elements. The primary element should be replaced after a year’s service or after cleaning no more than 6 times. Air-205 kPa (30 psi) Maximum Pressure 1. Insert a light inside the clean dry element and examine it. Discard the element if tears, rips or damage are found. 2.

Wrap and store good elements in a clean, dry place.. Direct air on the inside and outside of the element along the length of the pleats. Check the element for any tears, rips or damage. 162 WARNING