STRUCTURE AND FUNCTION CLSS 2. When the arm is being moved in, if bottom pressure B of cylinder (1) is greater than head pressure A , and the work equipment is in the digging process, check valve (4) closes and shuts off the circuit between the head and bottom ends. If pressure B at the bottom end rises further and exceeds 17.64 MPa (180 kg/cm 2 ), spool (5) of counterbal- ance valve (3) is actuated to maintain the area of the meter-out opening at the head end in order to ensure the digging force.
Operation When the arm is being moved in, if the word equipment is in the digging process, and pres- sure B at the bottom end of cylinder (1) rises, check valve (4) closes and the circuit between the head circuit and bottom circuit is shut off. If pressure B at the bottom end rises further, spool (5) of counterbalance valve (3) is pushed to the left in the direction of the arrow by pres- sure B . The oil from the regeneration circuit is connected to the tank circuit, and the area of the meter-out opening at the head end is made larger to ensure the digging force. 1. Arm cylinder 2. Arm spool 3. Counterbalance valve 4. Check valve 5. Spool Pp : Pump circuit (pressure) A :
Head circuit (pressure) B : Bottom circuit (pressure) T : Tank circuit (pressure) 10-85