STRUCTURE AND FUNCTION ELECTRONIC CONTROL SYSTEM 1) Control method in each mode Heavy-duty travel operation (H/O travel) mode Matching point in heavy-duty operation mode: Rated output point. When the load on the pump rises and the pres- sure rises, the engine speed goes down. When this happens, the pump discharge amount is reduced, and the engine speed is controlled so that it becomes rated speed. Just the cut-off at relief is cancelled and the oil flow at relief is increased. If the reverse happens and the pressure goes down, the system is controlled so that the pump discharge amount is increased until the engine speed reaches the rated speed.
By repeating this control, the engine can always be used at near the rated output point. Heavy-duty working (H/O work) mode Matching point in heavy-duty working operation mode: 90% partial output point. When the load on the pump rises and the pres- sure rises, the engine speed goes down. When this happens, mutual control of the en- gine and pump is used to control the system so that the pump absorption torque follows the equal horsepower curve of the engine, and the engine speed is lowered while keeping the torque constant. In this way, the engine is used in a range which provides good fuel efficiency.
10-139 Heavy-duty travel 75 kW (102 PS) operation (H/O travel) 2250 rpm Heavy-duty travel 66 kW (90 PS) operation (H/O travel) 1900 rpm