STRUCTURE AND FUNCTION ELECTRONIC CONTROL SYSTEM 1) Pump control function when traveling If the travel is operated in any working mode other than the heavy-duty operation (H/O) mode, this increases the pump absorption torque while keeping the working mode and en- gine speed as they are. # For details, see PUMP & ENGINE MUTUTAL CONTROL FUNCTION. 2) Travel speed selection function i) Manual selection using travel speed switch. If the travel speed switch is set to Lo, Mi, or Hi, the pump controller controls the pump flow and motor volume at each speed range as follows to switch the travel speed. 30 Km/h TRAVEL SPEED SPEC. 20 Km/h TRAVEL SPEED SPEC.
10-156 Travelspeed switch Lo(Low speed) Mi(Midran- gespeed) Hi(High speed) Pumpflow(%) 30 100 100 Motorvolume Max. Max. Min. Travelspeed (km/h) 3.5 10 30 Travelspeed switch Lo(Low speed) Mi(Midran- gespeed) Hi(High speed) Pumpflow(%) 30 100 100 Motorvolume Max. Max. Min. Travelspeed (km/h) 2.7 8 20