Komatsu — FUNCTION

STRUCTURE AND FUNCTION ELECTRONIC CONTROL SYSTEM 3) Pump pressure sensor 1. Plug 2. Sensor 3. Connector Function This sensor is installed to the inlet port circuit of the control valve. It converts the pump dis- charge pressure to a voltage and sends this to the controller. Operation When the pressurized oil entering from the pressure introduction portion pressurizes the diaphragm of the pressure detection portion, the diaphragm deflects and changes shape. A gauge layer is installed to the face opposite the diaphragm, and the resistance of the gauge layer converts the deflection of the diaphragm into an output voltage and sends it to the amp (voltage amplifier).

The voltage is further amplified by the amplifier and is sent to the pump controller. Relationship between P (kg/cm2) and output voltage (V) V = 0.008 x P + 1.0 # 1 kg/cm 2 = 0.098 MPa 10-158