Komatsu — TABLE OF JUDGEMENT STANDARD VALUE

TESTING AND ADJUSTING TABLE OF JUDGEMENT STANDARD VALUE Machine model PW130-6 20-4 Cate- gory Item Measurement conditions Unit Standard Permissible value value Operating force of control levers Travel control pedal • Engine at high idling • Hydraulic oil temperature: 45-550C • Measure max. value to end of travel N (kg) 337.5±107.5 (34.5±11) Max. 506 (Max 52) Hydraulic pressure Boom Normal RAISE Power max. Normal LOWER Power max. Normal • Hydraulic oil Power temperature: 45-55°C max • Relief pressure with Normal engine at high idling (Relieve only circuit to Power be measured) max • In H/O mode Normal MPa (kg/cm2) 31.85±1.47 (325±15) 31.85±2.45 (325±25) Power max.

34.79±1.47 (355±15) 34.79±2.45 (355±25) Normal 31.85±1.47 (325±15) 31.85±2.45 (325±25) Power max. 33.8 ±1.47 (345±15) 33.81±2.45 (345±25) Arm 31.85±1.47 (325±15) 31.85±2.45 (325±25) 34.79±1.47 (355±15) 34.79±2.45 (355±25) Bucket 31.85±1.47 (325±15) 31.85±2.45 (325±25) 34.79±1.47 (355±15) 34.79±2.45 (355±25) Swing 28.9±1.5 (295±15) 28.9±3 (295±30) Travel Stabilizer 34.79±0.98 (355±10) 34.79±1.96 (355±20) Pilot circuit pressure 3.2-3.5 (35-3) 3.2-3.5 (35-3) LS differential pressure • Hydraulic oil Levers at temperature: 45-550C neutral • Engine at Control high idling levers at neutral • In H/O mode Normal Pump Power relief max.

2.74±0.98 (28±10) 2.74±0.98 (28±10) PC valve output pressure (servo piston input pressure) 3.4±0.5 (35±5) 3.4±0.6 (35±6) Normal 15.97±1.47 (163±15) 15.97±2.45 (163±25) Power max. 17.44±1.47 (178±15) 17.44±2.45 (178±25)