Komatsu — E- 9 Engine speed is irregular

TROUBLESHOOTING E-9 E-9 Engine speed is irregular # Before carrying out troubleshooting, check that all the related connectors are properly inserted. # Always connect any disconnected connectors before going on the next step. a) Idling speed is irregular YES 2 When linkage be- tween governor motor and pump is adjus- ted, does condition become normal? 4 YES YES Is E218 displayed? Turn starting switch ON. See TESTING AND ADJUSTING. NO When linkage is dis- connected and motor lever is placed at po- sition engine low idling? 3 Starting motor signal 7 YES 1 NO Potentiometer 6 YES Is voltage between C03 (8) and chassis normal and stable? Is controller model code as shown in Table 1?

Turn starting switch ON. YES Is voltage between C03 (14) and (17) normal and stable? During operation 20 - 30V NO Fuel control dial 5 Turn starting switch ON. Set to monitoring code 03 or 02. Is voltage between C03 (4) and (17) normal and stable? At MIN: 2.9 - 3.3V NO NO At MIN : 4.0 - 4.75V NO NO Table 1 # The diagram shows monitoring code 03. 20-126