TROUBLESHOOTING E-9 b) There is hunting YES 2 4 YES YES Is E218 displayed? When linkage be- tween governor motor and pump is adjus- ted, does condition become normal? Turn starting switch ON. NO 3 Starting motor signal 7 YES When linkage is dis- connected and motor lever is placed at po- sition engine low idling? YES Is voltage between C03 (8) and chassis normal and stable? 1 NO Potentiometer 6 Is voltage between C03 (14) and (17) normal and stable? Is controller model code as shown in Table 1? Turn starting switch ON. Turn fuel control dial from MIN to MAX and stop also at midway position. YES During operation? 20 - 30V NO Turn starting switch ON. Set to monitoring code 03 or 02.
Fuel control dial 5 At MIN :2.9 - 3.3V At MAX : 0.5 - 0.9V NO Is voltage between C03 (4) and (17) normal and stable? NO At MIN : 4.0 - 4.75V At MAX : 0.25 - 1.0V NO NO Table 1 # The diagram shows monitoring code 03. 20-128