TROUBLESHOOTING E-10 E-10 Lack of output (engine high idling speed is too low) # Before carrying out troubleshooting, check that all the related connectors are properly inserted. # Always connect any disconnected connectors before going on the next step. YES 2 YES YES Is E218 displayed? Turn starting switch ON. YES 3 Potentiometer 6 Is voltage between C03 (14) and (17) normal and stable? Does injection pump lever contact FULL stopper? YES 1 NO Fuel control dial 5 Is voltage between C03 (4) and (17) normal and stable? At MIN :2.9 - 3.3V At MAX : 0.5 - 0.9V Is controller model code as shown in Table 1? Start engine. Set fuel control dial to MAX H/O mode. YES NO Turn starting switch ON.
Set to monitoring code 03 or 02. 4 At MIN : 4.0 - 4.75V At MAX : 0.25 - 1.0V Is adjustment of linkage between governor motor and pump normal? NO NO 8 YES When linkage between governor motor and pump is adjusted, does condition become normal? NO See TESTING AND ADJUSTING. NO NO Table 1 # The diagram shows monitoring code 03. 20-130