TROUBLESHOOTING E-12 E-12 Defective operation of battery relay system (engine does not stop) # This only occurs when the engine is stopped and the starting switch is turned OFF. Check with the engine stopped (push the fuel control lever of the fuel injection pump to the NO INJECTION position). # Before carrying out troubleshooting, check that all the related connectors are properly inserted. # Always connect any disconnected connectors before going on the next step. Note 1: When the starting switch is ON, the controller end is OFF, but a voltage of approx. 20 - 30V is always from starting switch BR, so if the voltage is measured at C01 (1), there is a voltage of 20 - 30V.
20-134 Cause Remedy YES See E-6 - 1 Is E315 displayed? YES Defective governor, pump Replace Relay drive signal 2 controller • Turn starting switch Is display of monitor- ON. NO ing code 35 as shown 2 YES in Table 1? Defective battery relay Replace Is resistance between • Turn starting switch C01 (female) (1) and bat- OFF. tery relay terminal BR, • 20 - 30V NO and between wiring har- 1) Disconnection in wiring ness and chassis normal? harness between C01 Replace • Between C01 (fe- NO (female) (1) - battery male) (1) and battery relay BR relay BR: MAX. 1 • Between wiring har- ness and chassis: 2) When light is connected Max. 1 M • Turn starting switch OFF.
• Disconnect C01 and battery relay BR. Table 1 Cause Remedy