Komatsu — A3 A3 C- 1 Abnormality in controller power source system ( controller LED is OFF)

TESTING AND ADJUSTING C-1 C-1 Abnormality in controller power source system (controller LED is OFF) # This troubleshooting is carried out when there is still an abnormality, so when disconnecting the connector and inserting the T-adapter, or when removing the T-adapter and returning the connector to its original position, if an E service code is not displayed, the problem has been removed. # Check that fuse 1 is not blown. # Before carrying out troubleshooting, check that all the related connectors are properly inserted. # Always connect any disconnected connectors before going on to the next step. # When the starting motor rotates normally.

(If the starting motor also does not rotate, go to E-8.) C-1 Related electric circuit diagram 20-174 YES 1 Is voltage between C01 (7) (13) and c02 (11) (21) normal? 2 YES Is voltage between • Turn starting switch fuse 1 and chassis ON. NO normal? • 20 - 30 V • Turn starting switch NO ON. • 20 - 30V Cause Remedy Defective governor, pump controller Defective contact or disconnection in wiring harness between fuse 1 and C01 (female) (7) (13) Defective contact, or disconnection in wiring harness between fuse 1 - H15 (2) - M14 (2) (1) - battery relay M Replace Repair or replace Repair or replace