TESTING AND ADJUSTING TROUBLESHOOTING M-1 M-1 [E101] Abnormality in error data is displayed [E102] Error in clock data is displayed # This is not an abnormality. It occurs during troubleshooting when disconnecting and connecting connector P02 (for the monitor panel electrical system), fuse No. 13, connector H14, connector M11, battery relay terminal B, or the battery terminal. (When the monitor panel power source circuit is shut off with the starting switch turned OFF) # If the service code display appears again after the system has been reset, carry out troubleshooting as follows. # Before carrying out troubleshooting, check that all the related connectors are properly inserted.
# Always connect any disconnected connectors before going on the next step. Note 1: Resetting operation: Turn the starting switch OFF. Then keep the time switch at the back of the monitor panel depressed, switch the starting switch ON again, and keep the time switch depressed for 5 seconds to return the system to normal. (With this operation, all the service codes in the internal memory are erased.) M-1 Related electrical circuit diagram 20-242 2 YES YES Is voltage between P02 (8) (14) chassis 1 normal? Does service code display appear again • Turn starting switch NO after system has OFF. been reset? • 20-30V.
• After resetting system, carry out NO normal operations for a short time and wanted the condition. (See note 1) Cause Remedy Defective monitor panel Disconnection, defective contact, short circuit with ground in wiring harness between battery - battery relay B - M11 (1) (2) - H14 (1) - fuse No. 13 - P02 (female) (8) (14) Normal Replace Repair or replace -