Komatsu — M- 6 When starting switch is turned ON, none of the lamps on the monitor panel light up for 3 seconds

TESTING AND ADJUSTING TROUBLESHOOTING M-6 M-6 When starting switch is turned ON, none of the lamps on the monitor panel light up for 3 seconds # Check that fuses No. 10 and 13 are not blown. # Before carrying out troubleshooting, check that all the related connectors are properly inserted. # Always connect any disconnected connectors before going on the next step. a) None of lamps in monitor panel light up. b) Some of lamps on monitor panel do not light up. 20-246 YES 2 Is voltage between P01(9) and chassis normal? 3 YES • Turn starting switch Is voltage between 1 ON. fuse No. 10 and • 20-30V NO chassis normal? Is voltage between P02 (8) (14) - (1) (9) • Turn starting switch NO normal? ON.

• 20-30V • Turn starting switch ON. 4 YES • 20-30V Is Voltage between fuse No. 13 and NO chassis normal? • Turn starting switch NO ON. • 20-30V Cause Remedy Detective monitor panel Disconnection, detective contact, short circuit with ground in wiring harness between P01 (female) (9) and fuse No. 10 Disconnection, defective contact, short circuit with ground in wiring harness between fuse No. 10 - H05 (2) - M14 (2) (1) - battery relay M Disconnection, detective contact, short circuit with ground in wiring harness between P02 (female) (8) (14) and fuse No. 1 Disconnection, defective contact, short circuit with ground in wiring harness between fuse No.

13 - H14 (2) - M11 (2) (1) - battery relay B Replace Repair or replace Repair or replace Repair or replace Repair or replace Cause Remedy Detective monitor panel Replace