TESTING AND ADJUSTING TROUBLESHOOTING TROUBLESHOOTING M-28 M-28 Defective coolant level sensor system. # Remove the coolant level sensor when carrying out troubleshooting. Table Note 1 Variations in coolant level The coolant level may change according to the angle of the machine, or the swaying of the machine, so if there is any display, check the coolant level again with the machine at a horizontal place. Note 2: If the problem occurs again, the connector (female) at the chassis end is probably defective, so check the connector and wiring harness at the chassis end. Note 3: Check for vibration at the connector mount. If there is excessive vibration, take the appropriate action. Note 4:
Defective installation is a possible cause, so be careful installing. If the problem occurs again, check for any vibration of the mount, and if there is excessive vibration, take the appropriate action. 20-268 YES 2 Is any foreign YES material (dirt) stuck to moving part of 3 YES float? Is there any large 1 crack, chip of damage to float? When float is moved up and down, is resis- tance between con- NO NO nector (1) and flange as shown in table 1? 4 YES Check wiring harness NO visually. Is it broken?
NO Cause Remedy Defective movement of float due to dirt Resonance of mount (See Note 2) Defective contact of connector (See Note 2) Disconnection in wiring harness (See Note 3) (defective clamp) external force applied) Defective sensor Clean Replace sensor (See note 4) Clean connector or replace Replace sensor Replace Float UP Max. 1Ω Float DOWN Min. 1 MΩ