STRUCTURE AND FUNCTION PPC PUMPLESS SYSTEM OPERATION The PPC pumpless system utilizes the return line oil from the power brake valve. Oil is supplied to the steering/braking circuits from a gear pump driven by the engine. Oil flow is prioritized to the steering cir- cuit via the priority valve with the remaining oil flow feeding the power brake valve. The return line from the brake valve passes through a pressure reducing valve where the oil pressure is maintained at 35 bar. This pressure is utilized to charge the PPC circuit. 0 -3 10-57