STRUCTURE AND FUNCTION CLLS BASIC PRINCIPLE 1. Control of pump swash plate angle The pump swash plate angle (pump discharge amount) is controlled so that LS differential pressure PLS (the difference between pump pressure PP and control valve outlet port LS pressure PLS ) (load pressure of actuator) is constant.
(LS pressure PLS = Pump discharge pres- sure PP - LS pressure PLS ) If LS differential pressure PLS becomes lower than the set pressure of the LS valve (when the actuator load pressure is high), the pump swash plate moves towards the maxi- mum position; if it becomes higher than the set pressure of the LS valve (when the actuator load pressure is low), the pump swash plate moves towards the minimum position. 10-69