Komatsu — METHOD OF LOWERING DUMP BODY IN EMERGENCY

. OPERATION TROUBLESHOOTING METHOD OF LOWERING DUMP BODY IN EMERGENCY WARNING 1. Remove hydraulic tank cap (F) and release the remaining pressure in the hoist circuit. hydraulic tank grip (3) clockwise to close the valve, then tighten locknut (2). If the dump body does not go down even when the above 3 - 128 There is danger of being trapped by the dump body, s o when lowering the dump body in an emerg ency, always carry out the operation from the ground and do n ot go under the du mp body When the dump body needs to b e lowered to the seat while the engine cannot be started f or some trouble, perform the following pro 2. Loosen lock nut (2) of manua l lower valve (1). 3.

Turn grip (3) of valve (1) cou nterclockwise. 4. The oil in th e hoist cylinder p body lowers. mp body goes and the dum When the du method is us ed, please cons ult your Komats u distributor.