Komatsu — WHEN ERROR CODE F-09 IS DISPLAYED (PROCEDURE FOR REPLACING BATTERY)

. ATTACHMENTS, OPTIONS HANDLING PAYLOAD METER II (CARD TYPE) WHEN ERROR CODE F-09 IS DISPLAYED (PROCEDURE FOR REPLACING BATTERY) The payload meter has an internal battery to prevent the recorded data from being deleted when the key in the REPLACING BATTERY CAUTION Parts to prepare Crosshead screwdriver New battery (581-86-55710) NOTICE 6 - 60 starting switch is turn ed to the OFF position If the voltage of the b attery drops, F-09 is di splayed a s an error message , so r eplace the batte ry as When replacing the batt ery, unload the machine and move i t to a saf e place NOTICE when carrying out the operation.

Remove your gloves when carrying out the op Be careful not to let a ny dirt or metal particles get inside the c ontroller. Be careful not to drop any nuts or washers ins ide the controller. 1. T urn the key in th e starting switch to the ON position and download the da ta stored i n the payload meter ersonal compute r, or carry out the me mory card dump o peration When doing this, do not 2. Return the startin g switch to the OFF po 3. Remove 4 screws (1) (M6) holding the pa yload meter, then pull t he payload mete r to the front. 4. Remove the conn ector, remove screws (3) (top s urface M3 x 9 r , left face M3 x 4) from top cover (2) of th e payload meter, then emove left side c over (4).