CHARGING SYSTEM I ELECIIiiii I TROUBLESHOOTING BATTERY IS NOT CHARGED. ~ 1. Connect: • Pocket tester (to battery terminals) 2. Measure: OUT OF SPECIFICATIONS i • Battery voltage • Fluid gravity Battery voltage: ~ more than 12 V at 20°C (68°F) • Check the battery. (See page 2-28) • Replace and/or charge battery. ~OK 1. Start the engine and accelerate to 3,000 rpm. 2. Measure: • Charging voltage Charging voltage: 13.3 ... 14.3 V /3,000 rpm. I DC20V I 1 - ~ўI 1 - + '--- Never disconnect battery cables while generator is operating or rectifier and regulator will be damaged . .. LESS THAN 13.3V FAULTY 1 Check the fuse, rectifier and charging coil. ~OK I Correct connecter.
Replace the fuse, rectifier and/or charging coil. 8-17 http://ReadManuals.com