Yamaha Exciter II-570 — Signal System

________________________ S_IG_N_AL_S_V_S_TE_M_IELECIIiiI 8E241 THERMO SYSTEM 1. Disconnect the thermo switch lead (Green/ Red) and remove the thermo switch ill. Handle the thermo switch with special care. Never subject it to strong solvents or allow it to be dropped. Should it be dropped, it must be replaced. 2. Connect the Pocket Tester ill (90890-03112, YU-03112) to the thermo switch ®. NOTE: ______________________ __ CD ~ ~~ Set the tester selector to"n x 1" position. 0 + 3. Immerse the thermo switch in coolant ® and check the thermo switch for operation. Coolant Operation temperature Less than The switch is open.

9S·C (209·F) (oon) 9S·C (209·F) The switch is closed.(On) or more @ Temprature gauge. Never heat the coolant to a temperature of 120· C (24S.5·F) or more. 4. If the thermo switch operation is incorrect, replace it. S.lnstali the thermo switch, and connectthermo switch lead. Thermo switch: 34.3 Nm (3.5 m • kg, 25 ft Ib) Avoid overtightening. 8-34 http://ReadManuals.com