Yamaha Exciter II-570 — Maintenance Specifications

MAINTENANCE SPECIFICATIONS 1 SPEC 1 0--1 Model EX570(E)T I EX570STT I EX570SXT Cooling System: Water Pump Drive Belt Tension 8 mm/8 kg (0.3 in/17.6Ib) 8 mm/13 - 20 kg (0.31 in/28.7 - 44.1 Ib) (NEW BELT) Filler Cap Opening Pressure 80 - 100 kPa (0.8 - 1.0 kg/cm2, 11 - 14 psi) Thermostat Opening Temperature 50 - 55·C (122 - 131·F) Thermostat Valve Lift 8 mm (0.3 in) at 70·C (158.5·F) Water Pump Type Impeller Type Coolant Type High quality ethylene glycol anti-freeze containing corro- sion inhibitor Coolant Mixing Ratio (Coolant:

Water) 3:2 Coolant Capacity 4.2 L (3.7 Imp qt, 4.4 US qt) 4.6 L (4.05 Imp qt, 4.86 US qt) (EX570ST) Reservoir Tank Capacity 0.25 L (0.22 Imp qt, 0.26 US qt) For EX570(E)/ST ~ High Altitude Settings -30°C -20°C -10°C O°C 10°C 20°C Altitude (-22°F) (-4°F) (14°F) (32°F) (50°F) (6~OF) I I I I I #310 (STO), IN: 3rd (STO) - 100 - 600 m (300 - 2,000 tt) (0 - 300 tt) .. #310 (STO), IN: 3rd (STO) - #320, IN: 3rd - 0- 100 m 4 #300, IN: 3rd 600 - 1,200 m (2,000 - 4,000 tt) #300, IN: 3rd - .. #290, IN: 3rd 1,200 - 1,800 m (4,000 - 6,000 tt) #280, IN: 3rd - #270, IN: 3rd, AS: 7/8- 4 1,800 - 2,400 m (6,000 - 8,000 tt) #260, IN: 3rd - 4 #250, IN: 3rd, AS: 7/8- 2,400 - 3,000 m (8,000 - 10,000 ft) #250, IN:

3rd - .. #240, IN: 2nd, AS: 7/8- #: Main jet number IN: Jet needle clip position AS: Air screw turns out 9-5 http://ReadManuals.com