OPERATION TROUBLESHOOTING 5. Connect the other clip of booster cable (B) to the engine block of the problem machine. Starting the engine 1. Make sure the clips are firmly connected to the battery termi- nals. 2. Start the engine of the normal machine and keep it to run at high idling speed. 3. Turn the starting switch of the problem machine to the START position and start the engine. If the engine doesn’t start at first, try again after 2 minutes or so. Disconnecting the booster cables After the engine has started, disconnect the booster cables in the reverse of the order in which they were connected. 1. Remove one clip of booster cable (B) from the engine block of the problem machine. 2.
Remove the other clip of booster cable (B) from the negative (-) terminal of the normal machine. 3. Remove one clip of booster cable (A) from the positive (+) ter- minal of the normal machine. 4. Remove the other clip of booster cable (A) from the positive (+) terminal of the problem machine. AD052981A OTHER TROUBLE ELECTRICAL SYSTEM G ( ): Always contact your Komatsu distributor when dealing with these items. G In cases of abnormalities or causes which are not listed below, please contact your Komatsu distributor for repairs.
161 Problem Main causes Remedy Lamp does not glow brightly even when the engine runs at high speed G Defective wiring G Defective adjustment of fan belt tension G (Check, repair loose terminals, disconnections) G Adjust fan belt tension For details, see EVERY 250 HOURS SERVICE Lamp flickers while engine is run- ning Charge level monitor does not go out even when engine is running G Defective alternator G Defective wiring G (Replace) G (Check, repair) Abnormal noise is generated from alternator G Defective alternator G (Replace)