OPERATION TROUBLESHOOTING G In cases of abnormalities or causes which are not listed below, please contact your Komatsu distributor for repairs.

163 Problem Main causes Remedy Engine oil pressure monitor lights up G Engine oil pan oil level is low (sucking in air) G Clogged oil filter cartridge G Defective tightening of oil pipe joint, oil leakage from damaged part G Defective engine oil pressure sensor G Add oil to specified level, see CHECK BEFORE STARTING G Replace cartridge, see EVERY 250 HOURS SERVICE G (Check, repair) G (Replace sensor) Steam is emitted from top part of radiator (pressure valve) G Cooling water level low, water leakage G Loosen fan belt G Dirt or scale accumulated in cooling system G Clogged radiator fin or dam- aged fin G Defective thermostat G Loose radiator filler cap (high altitude operation) G Defective water level sensor G Add cooling water, repair, see CHECK BEFORE STARTING G Adjust fan belt tension, see EVERY 250 HOURS SERVICE G Change cooling water, clean inside of cooling system, see WHEN REQUIRED G Clean or repair, see EVERY 500 HOURS SERVICE G (Replace thermostat) G Tighten cap or replace packing G (Replace sensor) Radiator water level monitor lights up Engine does not start when start- ing motor is turned.

G Lack of fuel G Air in fuel system G Defective fuel injection pump or nozzle G Starting motor cranks engine sluggishly G Preheating monitor does not light up G Defective compression G Defective valve clearance G Add fuel, see CHECK BEFORE STARTING G Repair place where air is sucked in, see EVERY 500 HOURS SERVICE G (Replace pump or nozzle) G See ELECTRICAL SYSTEM G (Adjust valve clearance) Exhaust gas is white or blue G Too much oil in oil pan G Improper fuel G Add oil to specified level, see CHECK BEFORE STARTING G Change to specified fuel Exhaust gas occasionally turns black G Clogged air cleaner element G Defective nozzle G Defective compression G Defective turbocharger G Clean or replace, see WHEN REOUIRED G (Replace nozzle) G (See defective compression above) G Clean or replace turbo-charger Combustion noise occasionally makes breathing sound G Defective nozzle G (Replace nozzle) Abnormal noise generated (com- bustion or mechanical).

G Low grade fuel being used G Overheating G Damage inside muffler G Excessive valve clearance G Change to specified fuel G Refer to “Radiator water level monitor lights up” as above G (Replace muffler) G (Adjust valve clearance)