Komatsu — CLEAN FRESH AIR INTAKE FILTER

SERVICE PROCEDURE MAINTENANCE. CLEAN FRESH AIR INTAKE FILTER 1. Remove two wings nuts holding retaining strap (2). 2. Grasp filter element (3) centrally and pull out of housing. 3. Note that filter element is a sandwich of a fine filter and a coarse filter. Clean filter by placing element in a mixture of hand hot water and neutral detergent with the coarse filter side downwards. Move element up and down to release dirt. (A) Coarse (outside) (B) Fine (inside) Rinse filter with clean water from the fine filter side. 4. Dry filter, compressed air may be used, but apply air from fine filter side. 5. Refit filter element ensuring coarse filter side is facing out- wards.

NOTICE The normal cleaning interval is 100 hours, however if the machine is used in a dusty environment, shorten this inter- val. 210