Komatsu — METHOD OF OPERATION

OPERATION TEMPERATURE CONTROL SWITCH The temperature can be adjusted with this switch (5) without hesitation, from low to high temperature. The temperature level indicator lamp lights to display the temperature of the air coming from the vents. The more the blue lamps that light, the lower the temperature while the more red lamps that light the warmer the temperature. The color of the indicator lamps change while the switch is being pressed. When the temperature reaches the desired level, release the switch to set the temperature. The settings for each mode are retained in memory even when the starting switch is turned OFF. However, in the following cases the settings must be made again:

When the machine has been out of use for more than seven days. When the battery voltage is extremely low. When there has been abnormal interference from outside. When the fan switch is turned OFF (the setting is not kept in memory with only the air conditioner switch on). If the air conditioner is used in the FRESH position, the inside of the cab will be pressurized and this will prevent the entry of dust. The higher the speed of the fan, the more effective the pressurizing becomes.

METHOD OF OPERATION WA480-5L 2-57 Switch Condition Of Use Fan Switch Air Conditioner Switch Temperature Control Switch FRESH/RE- CIRC Air Changeover Switch Mode Selector Switch Cooling Rapid HI ON All blue RECIRC FACE Normal HI - LO ON More than half are blue FRESH FACE Dehumidifying, Heating HI - LO ON More than half are red FRESH FOOT Heating Rapid HI OFF All red RECIRC FOOT Normal HI - LO OFF More than half are red FRESH FOOT Defroster HI ON More than half are red FRESH DEF Ventilation or Pressurizing HI - LO OFF All blue FRESH FACE