Komatsu — CHASSIS

MAINTENANCE 3-8 WA480-5L Cooling fan (Waste Handler) Cooling fan runs forward but will not reverse in AUTO mode FORWARD/REVERSE timer “reverse” time set too short. FORWARD/REVERSE timer “forward” time set too long. Check operation in MANUAL mode. If fan does not reverse, than service is required. Keep in mind that there is an 8 second coast period in between direction changes. If fan does reverse, then switch back to AUTO mode and continue to the next step. Check FORWARD/REVERSE timer scale selection. Normally “3”. Check reverse time unit selector switch setting. Nor- mally “10s” Increase reverse time by turning the reverse setting knob clockwise. Normally set to “1.5”.

Check forward time unit selector switch setting. Normally “hrs”. Decrease forward time by turning the forward setting knob counterclockwise. Normally set to “0.5” )Check, repair) Cooling fan runs in reverse continually in AUTO mode. FORWARD/REVERSE timer “reverse” time set too short. FORWARD/REVERSE timer “forward” time set too long. Check operation in MANUAL mode. If fan does not reverse, than service is required. Keep in mind that there is an 8 second coast period in between direction changes. If fan does reverse, then switch back to AUTO mode and continue to the next step. Check FORWARD/REVERSE timer scale selection. Normally “3”. Check forward time unit selector switch setting.

Normally “hrs”. Increase reverse time by turning the reverse setting knob clockwise. Normally set to “0.5”. Check reverse time unit selector switch setting. Normally “10s” )Check, repair)