12. OPERATION 12.9 HANDLING ACTIVE MODE Make full use of the active mode to match the purpose and condi- tions of the operation in order to carry out operations effectively and efficiently. The active mode selector switch can be turned ON (lights up) in order to provide quick leveling operations and effective deep digging and loading operations. ON lights up: Active mode ON ON goes out: Active mode cancelled The On lamp is off when the engine is started. If it is turned ON (lights up), it is possible to enter the active mode from any working mode. Even when it is turned ON (lights up), the working mode display does not change.
When the lamp goes out, the system returnes to the original working mode. REMARK Use the active mode with the fuel control dial turned to the MAX position. If it is not at the MAX position, it will be impossible to achieve a suitable increase in the work equipment speed. Active power-max function. When digging deep and loading, or rock raising use the active power-up function according to the following procedures. PC290-ENG 2-66 Mode Effective operation Advantages for operation Active mode Digging and loading The boom lowering speed is increases, so the cycle time for deep digging operations is reduced.
Leveling By increasing the arm IN speed and the pump response, the speed of rough leveling (light loads) is increased.